SIZE 4.5" wide x 10.5" high x 9.1" deep.
POWER REQUIREMENTS 89 to 135 volts ac.
60 +/- 3 Hertz 1 Amp SLO-BLO fusing
TEMPERATURE -34°C to +74°C Operating       -40°C to +85°C Storage
CHANNELS MONITORED 12 Channels with 4 inputs / channel (Green, Yellow, Walk, Red / Don't Walk).
16 Load Sensing Switch positions with 2 inputs / channel (input/output status, current).
2 Malfunction Response Module positions with 2 inputs / channel (output status, current).
MONITORED SIGNALS +24 Volt dc. (24VI and 24 VII)
48 ac field wire voltages (both polarities of sinusoid are monitored independent of one another). 36 Load Management System voltages.
DISPLAYED INFORMATION All active channels on 4 line x 20 character LCD.

THE FOLLOWIN