TSC logo

NEMA SMU-12/16 Level 2 Features and Specifications



FEATURES




BENEFITS



SPECIFICATIONS

SIZE 4.5" wide x 10.5" high x 9.1" deep.
POWER REQUIREMENTS 89 to 135 volts ac.
60 +/- 3 Hertz 1 Amp SLO-BLO fusing
TEMPERATURE -34°C to +74°C Operating       -40°C to +85°C Storage
CHANNELS MONITORED 12 Channels with 4 inputs / channel (Green, Yellow, Walk, Red / Don't Walk).
MONITORED SIGNALS Controller Voltage Monitor.
+24 Volt dc. (24VI and 24 VII)
48 ac field wire voltages (both polarities of sinusoid are monitored independent of one another).
DISPLAYED INFORMATION All active channels on 4 line x 20 character LCD.

THE FOLLOWING SHOWS OUTPUT TRANSMISSIONS OBTAINED ACROSS THE LCD FOR THE SMU-12/16 LEVEL 2 BY ACCESSING THE FRONT PANEL KEYPAD.

Copyright (c) 1993
Traffic Sensor Corp.
Rev.  G 2/9/93

>HELP

TIME hour:min:sec
DATE month/day/year
FAULT Disp Faults
MESSAGE Disp Mess
PGCARD Disp.  Prog.  C.
FLASHDLY Rly Dly
SETUP Setup Opt.
ERASE Setup Erase
DSPSETIUP DiSp.  Setup
SELFTEST Self Test
DONE


EXAMPLE:
TIME 5 30 30 
or
TIME 12:30:00

To display TIME:
TIME 

EXAMPLE:
DATE 05/26/91

To display DATE:
DATE 

The Fault comand is executed with the  keypad.
EXAMPLE:
FAULT                   Display recorded data

              1111111
     1234567890123456
----------------------
|FOO RRWWYR WR R     |  FIRST SCREEN FOR FAULT ENTRY #FOO
|CONFLICT IG 3Y      |  
|DATE 05/26/91 13:20 |
---------------------

               111111 
     1234567890123456
----------------------
|FOO RRWWYR WR R     |  NEXT SCREEN FOR FAULT ENTRY #FOO
|CONFLICT 1G 3Y      |  
|GGYR RYGG R         | 
----------------------


             1111111
     1234567890123456
-----------------------
|FOO RRWWYR WR R      |  NEXT SCREEN FOR FAULT ENTRY #FOO
|CONFLICT 1G 3Y       |   
|TF= 95 AC=116 24v=24 |
----------------------- 

EXAMPLE:
MESSAGE                    display recorded data

              1111111
     1234567890123456
----------------------
|MOO WY RRWGGRGR      |  FIRST SCREEN FOR MESSAGE ENTRY
|MIN FAIL 4Y          |  #MOO 
|DATE 04/27/91 10:45  |
-----------------------

             1111111
    1234567890123456
----------------------
|MOO WY RRWGGRGR      |  NEXT SCREEN FOR MESSAGE ENTRY
|MIN FAIL 4Y          |  #MOO 
|       RRRGYWGR      | 
-----------------------


              1111111
     1234567890123456
----------------------
|MOO WY RRWGGRGR      |  NEXT SCREEN FOR MESSAGE ENTRY
|MIN FAIL 4Y          |  #MOO 
|TF=113 AC= 98 24v=26 |
-----------------------



EXAMPLE:
PGCARD 
PROGRAM CARD
CHANNEL
                    111    Program Card Jumper location
Channels   123456789012
         1 XJ             <n>   Channel 1   Permissive with 2
         2  X J           <n>   Channel 2   Permissive with 4
         3   XJ           <n>   Channel 3   Permissive with 4
         4    X           <n>   Channel 4   Not Permissive
         5     X          <n>   Channel 5   Not Permissive
         6      X         <n>   Channel 6   Not Permissive
         7       X        <n>   Channel 7   Not Permissive
         8        X       <n>   Channel 8   Not Permissive
         9         X      <n>   Channel 9   Not Permissive
        10          X     <n>   Channel 10  Not Permissive
        11           X    <n>   Channel 11  Not Perinissive
        12            X   <n>   Channel 12  Not Permissive